From YouTube: City of Oldsmar Board of Adjustment Meeting, 3/24/2021
Description
No description was provided for this meeting.
If this is YOUR meeting, an easy way to fix this is to add a description to your video, wherever mtngs.io found it (probably YouTube).
A
A
A
B
B
C
B
A
C
A
C
Okay
welcome
this
is
wednesday
march
24
2001,
and
I'd
like
to
call
the
board
of
adjustment
meeting
to
order
if
we
would
stand
for
the
pledge
of
allegiance.
C
C
D
This
is
a
variance
request
to
increase
the
building
height
from
35
feet
to
45
feet,
and
the
variance
requires
to
reduce
the
width
of
ada
parking
spaces
from
15
feet
to
12
feet
and
the
variance
requires
to
reduce
the
number
of
ada
parking
spaces
from
15
spaces
to
8.
Spaces
variance
requires
to
reduce
the
width
of
the
regular
parking
spaces
from
10
feet
to
9
feet
in
order
to
develop
a
site
with
130
square
foot,
warehouse
building
in
the
m1
limited
manufacturing
district.
D
The
subject
property
has
a
zoning
designation
of
m1
limited
manufacturing
zoning
district
and
has
a
land
use.
Designation
of
industrial
limited
current
site
is
vacant
and
includes
a
stormwater
pond
that
was
permitted
as
part
of
the
dri
project.
The
request
was
reviewed
against
the
following
10
conditions
outlined
in
section
3.17.3
of
the
land
development
code.
D
Building
height
variance
the
maximum
building
height
in
the
m1
district
is
35
feet.
The
city
recently
redefined
the
building
height
as
the
vertical
distance
from
the
design
flood
elevation
to
the
highest
point
on
the
roof.
The
highest
point
on
the
roof
for
the
majority
of
the
proposed
building
is
at
37
feet.
Above
the
finish
floor
elevation
and
the
top
of
the
proposed
parapet
is
at
42.7
feet.
D
The
site
is
located
in
zone
x
and
the
design
flood
elevation
for
the
building
was
determined
to
be
at
elevation
17
feet
by
applying
the
18
inch
rule,
which
requires
minimum
finish
flow
elevation
to
be
18
inches.
Above
the
crown
of
the
adjacent
roadway,
the
crown
of
berkeley
boulevard
adjacent
to
the
site
is
at
elevation,
15.5
and
18
inches
above
that
elevation
is
elevation
17..
Typically,
the
dfe
for
the
site
is
the
same
as
the
finished
floor.
D
D
D
There
are
260
proposed
spaces
resulting
in
the
13
required
accessible
space
and
spaces
for
the
site
for
current
florida
building
code,
only
eight
accessible
spaces
would
be
required,
and
staff
also
recommends
that
the
city
of
oldsmore
land
development
code
should
be
amended
in
the
future,
because
these
local
higher
accessibility
centers
do
not
provide
meaningful
benefit
to
those
with
physical
disabilities,
while
causing
edit
challenge
reduced,
regular
parking
spaces
with
from
ten
feet
to
nine
feet.
Variance
per
section.
D
Granting
of
the
application
is
necessary
for
the
preservation
and
enjoyment
of
the
property
right
and
does
not
merely
serve
as
a
convenience
for
the
applicant.
The
future
structure
is
proposed
as
a
warehouse
building.
According
to
the
applicant,
there
has
been
a
documented
trend
over
the
last
20
years
to
increase
the
clear
height
inside
warehouse
buildings.
The
applicant
is
requesting
the
height
variant
so
that
he
can
construct
a
building.
That
means
current
demand
and
approval
for
the
variants
will
permit
the
applicant
to
construct
a
building
that
has
30
feet.
D
The
req,
the
request
is
not
the
result
of
an
action
by
the
property
owner
beforehand,
and
approval
of
the
variants
will
not
confirm
applicant
a
special
privilege
variances
to
the
building
height
and
parking
requirements
have
been
granted
in
the
past.
D
D
Requested
parking
width
variances
will
improve
the
overall
impervious
area
and
provide
more
green
space.
Current
m1
zoning
allows
the
impervious
ratio
of
80.
The
applicant
is
providing
a
ratio
59
over
the
entire
site,
which
means
that
over
40
percent
of
the
entire
site
will
remain
as
green
or
open
space.
D
This
request
is
not
based
on
the
applicant's
desire
to
secure
a
greater
financial
return,
as
mentioned
earlier.
Most
warehouse
construction
in
the
recent
years
has
been
of
the
structures
with
ceiling
clearance
of
28
to
36
feet.
The
applicant
is
proposing
a
structure
with
a
30
feet
of
clear
ceiling.
Height
approval
of
the
building
height
variants
will
not
be
detrimental
or
injurious
to
other
property,
or
improvements
in
the
neighborhood
in
which
the
property
is
located
proposed
building
will
be
37
feet
above
finish
floor
elevation,
while
only
parapet
will
be
at
11
at
elevation
42.7
feet.
D
C
Very
good,
thank
you
very
much.
Okay,
at
this
time,
does
the
board
have
any
questions
to
staff.
I
got
a.
B
D
Well,
it's
actually
an
hour
code
so,
and
I
listed
all
the
sections
from
our
code.
We
have
to
comply
with
our
local
land
development
regulations
where
we
stay.
The
parking
regular
parking
space
is
nine,
is
ten
by
twenty
and
the
applicant
is
asking
to
reduce
it
to
nine
feet
in
the
woods.
B
D
D
B
D
D
C
C
D
They're
reduced
regular
parking
spaces
will
be
reduced
to
nine
feet
instead
of
ten.
Yes,.
E
It
should
just
be
made
clear
that
the
applicant
isn't
asking
for
a
variance
from
the
florida
accessibility
code
which
is
embedded
in
the
in
the
building
code
or
the
americans
with
disabilities
act.
Nor
could
this
board
grant
such
a
variance
because
those
are
state
and
federal
laws.
So
really,
while,
while
the
report
says
it's
a
variance
from
ada,
it's
really
not
it's
a
it's
just
the
variance
from
the
parkinson's.
D
F
Quick
question
good
discussion
and
I
just
finished
with
the
ordinance
review
committee.
D
We
are
working
right
now
on
updating
those
ordinances,
so
we
have
a
list
of
they
will
go
to
the
attorney
first
and
then
they
will
be
presented
to
the
planning
board
and
the
city
council.
So.
F
D
Are
on
the
list
of
the
ordinances?
So,
yes,
they
are
on
our
board
of
things
to
be
done.
Yes,
thank
you
because
we
realize
that
it
causes
hardship
for
the
developers
and
every
other
case
that
comes
in
they're,
like
15
foot,
for
the
handicap
parking
most
of
them
demonstrate
demonstrate
present
to
us
as
the
12-foot
with
for
the
handicapped
parking
spaces,
and
then
we
comment
on
it
and
then
they
go
back
and
then
come
back
and
there
are
lots
of
variants.
C
Just
one
more
question:
do
you
know
the
height
of
the
nielsen
building
across
the
street.
D
I
was
going
to
check
that
and
I
believe
it's
close
to
45
feet
as
well.
So
if
you
need
the
additional,
I
can
get
back
with
you
on
that.
So.
B
A
C
C
Okay
and
being
there's
three
separate
variances
on
this
single
request,
I'd
like
to
do
this
one
at
a
time,
please!
Oh
there's,
four,
all
right!
Okay!
Thank
you.
Okay.
The
first
variance
request
is
a
requested
variance
to
increase
the
building
height
from
35
to
45
feet,
make
a.